o
odin.langpkg.dev
packages / tool / solarman_v5-sofarsolar_25_50KTLX_G3_validator

solarman_v5-sofarsolar_25_50KTLX_G3_validator

c0a964atool

Validator tool to discover, dump and display some information about sofarsolar 25~50KTLX-G3 inverters using the solarman LSW-3 wifi dongle

GPL-3.0 · updated 2 years ago

Validator tool to discover, dump and display some information about sofarsolar 25~50KTLX-G3 inverters using the solarman LSW-3 wifi dongle

This tool is by no means meant for production, and is very much held together by tape, bt it might help someone.

Compilation

  1. Install odin
  2. run odin run src -- <args>

There are still a lot of hard coded values in main.odin that you may want to tinker with. Values in other files, especially if named, are sourced from standards or generally agreed upon and should not need to change.

Commands

  • src.exe discover:

    Send broadcast message to discover devices on the network.

  • src.exe dump <endpoint> <logger serial>

    Start attempting to dump all registers of the inverter into out2.txt. Reading registers is whitelisted by start register, so this steps through every register and attempts to get 16 regs from that start location. Will only log successful reads.

  • src.exe show <endpoint> <logger serial>

    Fetches some information (current output, history and input) from the inverter using hardcoded register addresses and displays it.

    Looks like

     register#0480: output:
     	mask: 100000100001100001000011000010000110000101111111
     	grid frequency             : 49.98Hz
     	total output active   power: 0.059999999kW
     	total output reactive power: -2.46kW
     	total output apparent power: 3.1599998kW
     	total pcc    active   power: 0kW
     	total pcc    reactive power: 0kW
     	total pcc    apparent power: 0kW
     	phase R:
     		voltage              : 237.2V
     		output current       : 4.44A
     		output active   power: 0kW
     		output reactive power: 0kW
     		output power factor  : 0
     		pcc    current       : 0A
     		pcc    active   power: 0kW
     		pcc    reactive power: 0kW
     		pcc    power factor  : 0
     	phase S:
     		voltage              : 238.7V
     		output current       : 4.4299998A
     		output active   power: 0kW
     		output reactive power: 0kW
     		output power factor  : 0
     		pcc    current       : 0A
     		pcc    active   power: 0kW
     		pcc    reactive power: 0kW
     		pcc    power factor  : 0
     	phase T:
     		voltage              : 237.1V
     		output current       : 4.4299998A
     		output active   power: 0kW
     		output reactive power: 0kW
     		output power factor  : 0
     		pcc    current       : 0A
     		pcc    active   power: 0kW
     		pcc    reactive power: 0kW
     		pcc    power factor  : 0
     register#0680: historic production:
     	mask: 111111111111111111111111
     	generation today      : 3.6099999kWh
     	generation total      : 164.5kWh
     	load consumption today: 3.6099999kWh
     	load consumption total: 164.5kWh
     register#0580: string info:
     	mask: 1111111111111111
     	string#1
     		voltage : 572.79999V
     		amperage: 0.099999994A
     		power   : 0.059999999kW
     	string#2
     		voltage : 584.4V
     		amperage: 0.02A
     		power   : 0.0099999998kW
     	string#3
     		voltage : 554.7V
     		amperage: 0.099999994A
     		power   : 0.049999997kW
     	string#4
     		voltage : 608.2V
     		amperage: 0.119999997A
     		power   : 0.07kW
     	string#5#
     		...
    